PAIR Technologies
PAIR Technologies PAIR Technologies

美國PAIR Technologies
美國PAIR技術(shù)公司開發(fā)一種新型傳感器“平面陣列紅外線光譜儀”,它可以在較低濃度下在液體和氣體中識別生物和化學(xué)因子,檢測時間低于1秒。新的光譜譜儀沒有移動部件,依靠焦平面陣列(FPA)探測器。

  “這是現(xiàn)有的技術(shù)的一個良好的替代技術(shù),”該技術(shù)的創(chuàng)始人之一大通布魯斯博士說,“該儀器沒有移動部件,輕巧耐用,體積小,便于攜帶,可以隨身攜帶它到牙醫(yī)辦公室。“

  目前的檢測技術(shù)是基于傅立葉變換紅外(FT - IR光譜)光譜法,需要數(shù)十分鐘的化學(xué)分子指紋識別。一傅立葉變換紅外光譜法(FTIR)是一種重要的分析測試手段。近年來,儀器聯(lián)用等新技術(shù)的不斷發(fā)展,使FTIR的應(yīng)用范圍日益廣泛,成為鑒別未知污染物和環(huán)境監(jiān)測的重要工具。
研究發(fā)現(xiàn),高精度聲譜儀能夠早期檢測疾病、化學(xué)武器和環(huán)境污染物。

Planar array IR (PA-IR) is a patented technology licensed from the University of Delaware that uses a variety of dispersive elements to separate and display the individual wavelength components from a standard IR continuum light source onto the pixels of a focal plane array (FPA) (e.g., a 256 x 256 MCT) detector. The detected image can be immediately converted to a spectrum by either plotting intensity versus pixel location for a single row or by first co-averaging ("binning") a number of rows before carrying out this operation. Since pixel location within a given row can be previously calibrated to a corresponding frequency range, no Fourier transformation of the data is necessary and spectral information is obtained directly.

Since the PA-IR instrument contains a slit, image curvature occurs but proprietary software has been incorporated so as to remove any frequency variations from row-to-row due to misalignment of the spectra caused by image curvature. Because the PA-IR instrument incorporates an ultrafast FPA, it is capable of obtaining an IR spectrum in less than 100 μsec integration times (using a LN2 cooled 256 x 256 MCT FPA). This enables a whole range of kinetics and dynamics experiments to be carried out that were previously inaccessible with standard FT-IR instruments.

How do PA-IR and FT-IR compare?

Fourier transform IR (FT-IR) instruments use a Michelson interferometer to divide the amplitude of the IR source into 2 beams, which reflect off both a fixed and a moving mirror respectively. When the beams are recombined they generate an interference pattern, which is detected by a single element detector as a variation in intensity as a function of the optical path difference between the two beams. This interferogram must then be Fourier transformed to produce a power spectrum of energy vs. frequency. Two separate experiments must be run: one with no sample in the beam (reference) and a second one with the sample in the beam (sample). During and between the two runs the sample chamber must be purged with N2 gas so as to displace the H2O vapor from the instrument.


The PA-IR instrument passes the IR source through a sample and then uses dispersive optics to break up the IR source into its individual components, which then all impinge on a focal plane array (FPA) detector simultaneously. This multifrequency approach eliminates the necessity of carrying out a Fourier transformation of the data. In addition, PA-IR has been designed in a true double beam configuration so as to take advantage of the large number of pixels available in the FPA. Hence both beams of the double beam instrument can be incident on the FPA simultaneously providing both a "sample" and "reference" spectrum simultaneously. Since the path lengths of each of the two beams is identical, the background H2O vapor can be compensated for directly thereby removing the need for purging. Since the FPA is capable of less than 100 μsec integration times, the current speed of the instrument is governed by the electronic readout time (acquisition time), which is already decreasing from its current value of 17ms. In the near future it is anticipated that with improvements in the readout electronics, the acquisition time will approach the integration time providing an IR spectrum in < 100 μsec. In addition because there are no moving parts in a PA-IR instrument compared to standard FT-IR instruments, the PA-IR instruments are rugged, portable and scaleable providing new opportunities for IR spectroscopy in process monitoring, chemical warfare detection and health care evaluation.


How do PA-IR and FT-IR imaging compare?

Both PA-IR and FT-IR imaging use a focal plane array (FPA) and provide a spatial image. In the latter, an interferogram is produced at each pixel, which in a 128x128 array translates into approximately 18,000 Fourier transforms that must be carried out. However the information obtained represents a 2-dimensional map of chemical variation over the spatial region investigated. The PA-IR image contains less information because it represents essentially only spatial data in 1-dimension since the other dimension represents the wavelength dimension. However because of its speed (integration times < 100 μsec), a PA-IR image can be used to record real time changes in chemical information in that 1-D direction.


 

關(guān)于我們客戶服務(wù)產(chǎn)品分類法律聲明
主站蜘蛛池模板: 久久亚洲精品国产亚洲老地址 | 成综合人影院在院播放 | 丁香花成人论坛 | 国产91精品免费视频 | 秋霞日韩一区二区三区在线观看 | 久久国产精品免费一区 | 永久免费无码AV国产网站 | 桃色AV久久无码线观 | 日本久久久久 | 精品三级黄色片日韩三极片 | 亚洲无人区码一二三码区别图片 | 真实国产乱子伦精品一区二区三区 | 人与嘼在线A片观看免费 | 国产午夜爽爽窝窝在线观看 | 日韩性做爰免费A片AA片 | 四虎影视永久免费观看地址 | 日本黄H兄妹H动漫一区二区三区 | 丁香色狠狠色综合久久小说 | 久久久久小草精品免视看 | 久久久久夜色精品国产明星 | 麻豆精品无人区码一二三区别:重塑消费体验 | 免费无码一区二区三区A片18 | 囯产愉拍亚洲精品一区 | 另类春色小说 | 色噜噜综合熟女人妻一区 | 亚洲精品久久久久久一区 | 在线成人免费观看国产精品 | 亚洲 欧美 中文 AⅤ在线视频 | 人妻在客厅被C的呻吟 | 欧美性与交视频在线观看 | 亚洲欧美视频一区二区 | 五月激情四射开心网 | 国产熟睡乱子伦视 | 麻豆网站入口在线观看 | 国产经典三级av在线播放 | 精品AV综合导航 | 日韩国产一区二区三区在线 | 欧美日韩中文一区二区三区 | 国产精品精华液网站 | 久久婷婷五月综合色精品首页 | 波多野结衣电影在线观看电影免费在线观看 |